DSP-HR Series   Programmable DC Power Supply
Output Model Ripple Line regulation

 Load regulation

Response time(S) Remote
Sense
(V)
Size
CV CC CV CC CV CC CV CC  Full
Load
UP
Full
Load
Down 
No
Load
Down 
V A mV
rms
mA
rms
0.05%
+mV
0.1%
+mA
0.05%
+mV
0.1%
+mA
0 - 6
0 - 100
DSP-006-100HR 10 180 2.8 11 2.8 23 0.08 0.05 0.6 1 1UH
0 - 8
0 - 90
DSP-008-090HR 10 180 2.8 11 2.8 23 0.08 0.05 0.6 1 1UH
0 - 12.5
0 - 60
DSP-012.5-060HR 10 120 4 8.5 4 18 0.08 0.05 0.8 1 1UH
0 - 20
0 - 38
DSP-020-038HR 10 76 4 5.8 4 12.6 0.08 0.05 0.8 1 1UH
0 - 30
0 - 25
DSP-030-025HR 10 63 5 4.5 5 10 0.08 0.08 0.9 1.5 1UH
0 - 40
0 - 19
DSP-040-019HR 10 48 6 3.9 6 8.8 0.08 0.08 1 2 1UH
0 - 50
0 - 15
DSP-050-015HR 10 43 8 3.6 8 8.2 0.08 0.08 1.1 2 1UH
0 - 60
0 - 12.5
DSP-060-12.5HR 10 38 8 3.25 8 7.5 0.08 0.08 1.1 3 1UH
0 - 80
0 - 9.5
DSP-080-09.5HR 10 29 10 2.95 10 6.9 0.15 0.15 1.2 4 1UH
0 - 100
0 - 7.5
DSP-100-07.5HR 10 23 12 2.75 12 6.5 0.15 0.15 1.5 5 1UH
0 - 150
0 - 5
DSP-150-005HR 16 18 17 2.5 17 6 0.15 0.15 2 5 1UH
0 - 300
0 - 2.5
DSP-300-02.5HR 25 13 32 2.25 32 5.5 0.15 0.15 3 5 1UH
0 - 350
0 - 2.1
DSP-350-02.1HR 25 13 32 2.25 32 5.5 0.15 0.15 3 5 1UH
0 - 450
0 - 1.7
DSP-450-01.7HR 34 13 35 2.3 35 5.5 0.21 0.24 3.5 5 1UH
0 - 600
0 - 1.25
DSP-600-01.25HR 75 8 62 2.13 62 5.26 0.25 0.3 4 5 1UH
 
1U 1500W series specification :
Output Model Ripple Line regulation

 Load regulation

Response time(S) Remote
Sense
(V)
Size
CV CC CV CC CV CC CV CC  Full
Load
UP
Full
Load
Down 
No
Load
Down 
V A mV
rms
mA
rms
0.05%
+mV
0.1%
+mA
0.05%
+mV
0.1%
+mA
0 - 6
0 - 200
DSP-006-200HR 15 360 2.8 18.5 2.8 38 0.08 0.05 0.6 1 1U
0 - 8
0 - 180
DSP-008-180HR 15 360 2.8 18.5 2.8 38 0.08 0.05 0.6 1 1U
0 - 12.5
0 - 120
DSP-012.5-120HR 15 248 3.4 14.5 4 28 0.08 0.05 0.8 1 1U
0 - 20
0 - 76
DSP-020-076HR 15 152 4 9.6 4 20.2 0.08 0.05 0.8 1 1U
0 - 30
0 - 50
DSP-030-050HR 15 125 5 7 5 15 0.08 0.08 0.9 1.5 1U
0 - 40
0 - 38
DSP-040-038HR 15 95 6 5.8 6 12.6 0.08 0.08 1 2 1U
0 - 50
0 - 30
DSP-050-030HR 15 85 7 5.2 7 11.4 0.08 0.08 1.1 2 1U
0 - 60
0 - 25
DSP-060-025HR 15 75 8 4.5 8 10 0.08 0.08 1.1 3 1U
0 - 80
0 - 19
DSP-080-019HR 15 57 10 3.9 10 8.8 0.15 0.15 1.2 4 1U
0 - 100
0 - 15
DSP-100-015HR 15 45 12 3.5 12 8 0.15 0.15 1.5 5 1U
0 - 150
0 - 10
DSP-150-010HR 24 45 12 3.5 12 8 0.15 0.15 2 5 1U
0 - 300
0 - 5
DSP-300-005HR 38 25 32 2.5 32 6 0.15 0.15 3 5 1U
0 - 350
0 - 4.2
DSP-350-04.2HR 38 25 32 2.5 32 6 0.15 0.15 3 5 1U
0 - 450
0 - 3.4
DSP-450-03.4HR 68 18 35 2.5 32 5.8 0.21 0.24 3.5 5 1U
0 - 600
0 - 2.5
DSP-600-02.5HR 113 15 62 2.26 62 5.5 0.25 0.3 4 5 1U
 
2UH 1500W series specification :
Output Model Ripple Line regulation

 Load regulation

Response time(S) Remote
Sense
(V)
Size
CV CC CV CC CV CC CV CC  Full
Load
UP
Full
Load
Down 
No
Load
Down 
V A mV
rms
mA
rms
0.05%
+mV
0.1%
+mA
0.05%
+mV
0.1%
+mA
0 - 6
0 - 200
DSP-006-200HRB 15 360 2.8 18.5 2.8 38 0.08 0.05 0.6 1 2UH
0 - 8
0 - 180
DSP-008-180HRB 15 360 2.8 18.5 2.8 38 0.08 0.05 0.6 1 2UH
0 - 12.5
0 - 120
DSP-012.5-120HRB 15 248 3.4 14.5 4 28 0.08 0.05 0.8 1 2UH
0 - 20
0 - 76
DSP-020-076HRB 15 152 4 9.6 4 20.2 0.08 0.05 0.8 1 2UH
0 - 30
0 - 50
DSP-030-050HRB 15 125 5 7 5 15 0.08 0.08 0.9 1.5 2UH
0 - 40
0 - 38
DSP-040-038HRB 15 95 6 5.8 6 12.6 0.08 0.08 1 2 2UH
0 - 50
0 - 30
DSP-050-030HRB 15 85 7 5.2 7 11.4 0.08 0.08 1.1 2 2UH
0 - 60
0 - 25
DSP-060-025HRB 15 75 8 4.5 8 10 0.08 0.08 1.1 3 2UH
0 - 80
0 - 19
DSP-080-019HRB 15 57 10 3.9 10 8.8 0.15 0.15 1.2 4 2UH
0 - 100
0 - 15
DSP-100-015HRB 15 45 12 3.5 12 8 0.15 0.15 1.5 5 2UH
0 - 150
0 - 10
DSP-150-010HRB 24 45 12 3.5 12 8 0.15 0.15 2 5 2UH
0 - 300
0 - 5
DSP-300-005HRB 38 25 32 2.5 32 6 0.15 0.15 3 5 2UH
0 - 350
0 - 4.2
DSP-350-04.2HRB 38 25 32 2.5 32 6 0.15 0.15 3 5 2UH
0 - 450
0 - 3.4
DSP-450-03.4HRB 68 18 35 2.5 32 5.8 0.21 0.24 3.5 5 2UH
0 - 600
0 - 2.5
DSP-600-02.5HRB 113 15 62 2.26 62 5.5 0.25 0.3 4 5 2UH
 
2U 3000W series specification :
Output Model Ripple Line regulation

 Load regulation

Response time(S) Remote
Sense
(V)
Size
CV CC CV CC CV CC CV CC  Full
Load
UP
Full
Load
Down 
No
Load
Down 
V A mV
rms
mA
rms
0.05%
+mV
0.1%
+mA
0.05%
+mV
0.1%
+mA
0 - 6
0 - 400
DSP-006-400HR 23 1000 2.8 42 6.2 85 0.08 0.02 0.5 1 2U
0 - 8
0 - 360
DSP-008-360HR 23 1000 2.8 42 6.2 85 0.08 0.02 0.5 1 2U
0 - 12.5
0 - 240
DSP-012.5-240HR 23 800 3.2 29 7.1 60 0.08 0.1 0.8 1 2U
0 - 20
0 - 150
DSP-020-150HR 23 600 4 18.5 8 38 0.08 0.1 0.8 1 2U
0 - 30
0 - 100
DSP-030-100HR 23 310 5 13 9.5 27 0.08 0.16 0.9 1.5 2U
0 - 40
0 - 76
DSP-040-076HR 23 250 6 10.5 11 22 0.08 0.16 1 2 2U
0 - 50
0 - 60
DSP-050-060HR 23 200 7 9 13 19 0.08 0.16 1.1 2 2U
0 - 60
0 - 50
DSP-060-050HR 23 150 8 7.5 14 16 0.08 0.16 1.1 3 2U
0 - 80
0 - 38
DSP-080-038HR 23 110 10 6.2 17 13.4 0.15 0.3 1.2 4 2U
0 - 100
0 - 30
DSP-100-030HR 23 90 12 5.3 20 11.6 0.15 0.3 1.5 5 2U
0 - 150
0 - 20
DSP-150-020HR 36 90 17 4.2 27.5 9.4 0.15 0.3 2 5 2U
0 - 300
0 - 10
DSP-300-010HR 57 50 32 3.1 50 7.2 0.15 0.3 3.5 5 2U
0 - 350
0 - 8.4
DSP-350-08.4HR 57 50 32 3.1 50 7.2 0.15 0.3 3.5 5 2U
0 - 450
0 - 6.8
DSP-450-06.8HR 134 42 43 2.8 84 6.7 0.25 0.5 4 5 2U
0 - 600
0 - 5
DSP-600-005HR 170 30 62 2.55 95 6.1 0.25 0.5 4 5 2U
 
  • All parameters are specified base on power on after 30 minutes, Ambient temperature 23±5℃ / Humidity : Under 80% RH, AC Voltage : ±5%, Frequency : ±5%.
  • Ripple Bandwidth=5 ~ 1MHz
  • The minimum output is 2V when measuring the ripple of 6V~20V models. The minimum output is 10% of the rated voltage/current when measuring other models.
  • Output transient response time: resistor load testing within rated output voltage.
  • Special requests on demand.
  • All specifications are subject to change without notice.
 

Previous

Next


Copyright 2019 CHYNG HONG ELECTRONIC CO., LTD.  |  Contact us