| EL 系列 直流電子負載 |
| 共同規格: |
|
PAGE 1 |
| SPECIFICATIONS | RATING/DESCRIPTION (note.7) | CONDITION | |
| Linearity vs. Programming Command | Constant Current | ±0.25% | 5-100% of Full Scale |
| Constant Power | ±2% | ||
| Constant Voltage | ±0.25% (50V models: ±1%) | ||
| Constant Resistance | ±1% | ||
| Constant Conductance | ±1% | ||
| Regulation | current | ±0.25% | 5-100% of Full Scale |
| voltage | ±1% | ||
| current | ±0.25% | ||
| voltage | ±1% | ||
| current | ±1% | ||
| Resolution (Via Computer Control) | 14 Bits | 5-100% of Full Scale | |
| Current Readback (Current Mode) |
Computer Accuracy | ±0.25% | 5-100% of Full Scale |
| Computer Resolution | ±15 Bits | 5-100% of Full Scale | |
| Parameter Readback (Current and Voltage) |
Accuracy | ±0.25% (50V models: ±1%) | Full range output |
| Resolution | ±15 Bits | 0.5% to 100% of nominal range | |
| USB Interface | Uses IEEE 488.2 and SCPI commands and queries |
Requires no cost downloadable driver | |
| RS 232 Interface | Uses IEEE 488.2 and SCPI commands and queries |
Baud rate: 38400 Parity: None Data Bits: 8 Stop Bits: 1 Echo: OFF |
|
| GPIB Interface | Uses IEEE 488.2 and SCPI commands and queries |
Optional card provides access to both interfaces. Add suffix "G" to model number when ordering. |
|
| Ethernet Interface | Uses IEEE 488.2 and SCPI commands and queries |
Optional card provides access to both interfaces. Add suffix "G" to model number when ordering. |
|
| a-c Line Power Input | 120V a-c ±10%, 50-60 Hz or 240V a-c ±10%, 50-60 Hz |
120V is factory default, 240V requires internal configuration |
|
| Operating Temperature | 0°C to 40°C | ||
| Dimensions (Load) | 19"W x 7"H x24.5"D | ||
| Weight (Load) | 88 lbs. | ||
| Storage Requirements | -20 to +60°C, 15 to 80% RH | Relatively dust free environment | |
| Parallel Operation | Master/slave | 15 slaves maximum per master. | |
| ● note.7 :
Specifications measured @23°C ambient. ● note.8 : Regulation specified after 15 minutes
of operation at set power level.
● note.9 : Individually fused FETs allow continued
operation with device failure.
● note.10 : Maximum operating power and current
may be reduced if operating conditions (ambient temperature, available air
flow, etc.)
cause internal load temperature to exceed safe operating conditions for
FETs (TEMP FAULT).
● note.11 : Maximum operating power and/or current
may be reduced when ambient temperature exceeds 25°C depending on air flow,
duty cycle of load operation and other conditions. |
|
|
|||
|
|||
|
Copyright 2026 CHYNG HONG ELECTRONIC CO., LTD. | Contact us |
|||