| KLP 系列 1U 可程式定電壓、定電流、定功率直流電源供應器 |
| 共同規格: |
|
PAGE 1 |
| SPECIFICATIONS | RATING/DESCRIPTION | CONDITION | |
| Stabilizer Type | CV/CC | Voltage/Current | |
| Adjustment Range | voltage | 0-100% of rated voltage | No minimum load required |
| current | min-100% of rated current(note.1) | ||
| Source Effect | voltage | 0.01% Emax | Over full source range |
| current | 0.01% lmax | ||
| Load Effect | voltage | 0.01% Emax | Over full load current range |
| current (note.2) |
0.01% lmax (note.3) |
||
| Temperature Effect | voltage | 0.02%/°C | 0-50°C |
| current | 0.05%/°C | ||
| Time Effect (drift) | voltage | 0.05%/24hr | After 30 minute warmup |
| current | 0.05%/24hr | ||
| Error Sensing | 0.25 volts per wire | Above rated output | |
| Isolation Voltage | 600V d-c or peak | Either output terminal to ground | |
| Transient Recovery for Load Change |
excursion | 1% of Emax | 50% load step 2A/μsec max |
| recovery | 2 msec | Return to 0.1% of setting | |
| Turn on / turn off Overshoot |
Same as load transient response limits | ||
| Overvoltage Protection |
voltage | 20-120% of Emax | User selectable recovery |
| Overcurrent Protection | current | 72-120% of Imax | User selectable recovery |
| Overtemperature Protection | Shutdown | User selectable recovery | |
| Output Lead Fault Protection | Shutdown | User selectable recovery | |
| Parallel Operation | Active load sharing within 5% of I0 rated | Up to 5 units maximum (note.4) | |
| AC Input voltage | nominal | 100-240V a-c |
Single phase Wide range |
| range | 100-255V a-c | ||
| DC Input voltage | range | 125-420V d-c | No regulatory agency approval |
| Input Frequency | nominal type | 50-60 Hz | Single phase |
| maximum | 45-440 Hz | Increased leakage above 66 Hz | |
| Power Factor | tpical | 0.99 | Meets EN 61000-3-2 typical |
| Maximum Input Current | 120V a-c | 13A rms | Rated load (1200W) |
| 240V a-c | 6.5A rms | ||
| Inrush Current | 265V a-c | 40A | Peak |
| 132V a-c | 20A | ||
| Input Fusing | Circuit Breaker | 2-line | |
| Low a-c Protection | Self Protected | No fixed limits | |
| Output Hold Up | typical | 10 milliseconds | Ride through |
| Leakage Current |
115V a-c, 60 Hz | 1.2mA max. | |
| 230V a-c, 50 Hz | 2.3mA max. | ||
| Dimensions | 44.45 x 482.6 x 443.7 mm | H x W x D | |
| Weight | 6.82kg | ||
| note.1 : See Model Table for minimum programmable current. |
| note.2 : After settling effect. |
| note.3 : For 600V model: 0.02% + 3.3μA/V of compliance voltage. |
| note.4 : E-Series models are not Master/Slave capable. |
| |
|||
| 以上規格及選購配備僅供參考,實際規格以KEPCO網站資料為準,或洽本公司業務人員 |
|||
| |
|||
| Copyright 2025 CHYNG HONG ELECTRONIC CO., LTD. | Contact us |
|||