| Output
frequency |
FIx : 50Hz /
60Hz ; Adjustable : 45.00~450.0Hz(note.1) |
| Frequency
resolution |
0.01Hz (45.00 ~ 99.99Hz)
, 0.1Hz(100.0 ~ 450.0Hz) |
| Frequency regulation |
Fix : ±1Count ; Adjustable : ±0.01Hz
at 40.00-99.99Hz , ±0.1Hz at 100.0-999.9Hz |
| Frequency temperature effect |
50 ppm / ℃ |
| Frequency response |
45Hz ~ 450Hz ( ±1db )(at output voltage
80% Full scale no load) |
| External input level |
45Hz ~ 450Hz ( 3.0Vrms Full scale) (Optional)(note.1) |
Output voltage
|
Standard : 0~150V / 0~300V
Optional : 0~300V / 0~600V (Special voltage on request) |
| Voltage temperature effect |
± 0.2% / ℃ |
| Output T.H.D. |
≦ 2% (at 120V-50/60Hz ) (0.1%/100Hz)
(at Resister Load ,PF=1,THD-R measurement)(to 80kHz BW) |
| Load regulation |
±0.2% (0.1%/100Hz)(at Resistor Load) |
| Line regulation |
±0.2% (ACV±10% ; THD≦2%;Frequency±5%)
(at 80% Fullscal ; LOAD=0~50% ; PF=1) |
| Allow crest factor of load current |
2.5 (at full load) (Rated current) |
| Power factor of load |
0.5~1(lead or Lag) |
|
Output
voltage ramp time
|
0.1Sec ~ 99.9Sec |
| Set accuracy |
Frequency ≦ 0.05% ± 1C (at 50/60Hz
; 0.05%/100Hz)
Voltage ≦ 0.1% ± 2C (at 50/60Hz ; 0.05%/100Hz) |
| Transient Response |
2mS |
| Circuit |
IGBT PWM Amplifier (Inverter) |
| Efficiency |
>85% (at 80%fullscal voltage ; Rated current) (watt
efficiency) |
Protections Function
|
- Over voltage protection ,
- Over current protection(120%) ,
- Line input over/under voltage protection (±15%) ,
- ±Sense cable loosen protection or compensation voltage>
5V ,
- Over temperature protection ,
- Output waveform CLIP alarm
|
| Cooling system |
Forced air-cooling type |
| Operating Temperature/Humidity |
0 ~ +45 ℃ / 10 ~ 90%RH |
| Insulation Resistance |
10MΩ .500VDC(line input terminal to casing) |
| Acoustic Noise |
70~80dB At 1 Meter Distance |