| D-HP Series Programmable DC Power Supply |
| General Specifications : | PAGE 1 |
| Panel setting resolution | 5 digits |
| Panel display resolution | 5 digits |
| Command setting resolution | ±0.002% of full scale |
| Command reading resolution | ±0.002% of full scale |
| Panel setting accuracy | Voltage : ±0.1% ± 3Count at rated voltage |
| Current : ±0.5% ± 3Count at rated current | |
| Panel display accuracy | Voltage : ±0.2% ± 3Count at rated voltage |
| Current : ±0.5% ± 3Count at rated current | |
| Command & DA setting accuracy |
Voltage ±0.01% ± 3Count at rated voltage |
| Current ±0.01% ± 3Count at rated current | |
| Command & AD Measurement accuracy |
Voltage : ±0.02% ± 2Count at rated voltage (Average Measurement) |
| Current : ±0.05% ± 3Count at rated current (Average Measurement) | |
| Current : ±0.4% ± 3Count at rated current (AC+DC)offset=50mA (True RMS) | |
| Watt : ±0.5% ± 3Count at rated power | |
| Analog setting accuracy(V) |
Constant Voltagemode(CV) : Voltage ± 5% |
| Constant Currentmode(CC) : Current ± 5% | |
| Analog monitor accuracy(V) |
Rate voltage output : 10.00V ± 0.25V; |
| Zero voltage output : 0.00V ± 0.25V; | |
| Rate current output : 10.00V ± 0.25V; | |
| Zero current output : 0.00V ± 0.25V; | |
| Line regulation | Voltage : ± 0.04% of full scale Current : ± 0.08% of full scale |
| Load regulation | Voltage : ± 0.05% of full scale Current : ± 0.1% of full scale |
| Command response time | ≤20ms (After received) (note.2) |
| Sequence time | 0.00~558060 sec |
| Ramp up / down time | 0~99.9 sec |
| Over voltage / Over current setting range |
0% ~ 110% of rated voltage ; 0% ~ 110% of rated rated current |
| Transient response time | Constant Voltage mode : 10~200ms(at Resistance load 10%~90%)(changes with different models) |
| Output Maximum | Voltage : 105% rated |
| Current : 105% rated | |
| Output slew rate | Output voltage 10 to 100% <1000mSec (changes with
different models) Output current 10 to 100% <500mSec (changes with different models) |
| Efficiency | > 85% (Rate voltage , Rate current) |
| Protective functions | Programmable over voltage protection(POVP), Programmable over
current protection(POCP), Over temperature protection(OTP), Fuse blown protection,Line input over/under voltage protection(±10%) |
| Withstand voltage | Primary - Chassis : No abnormalities AC 2000V for 1 minute Primary - Secondary : No abnormalities AC 2000V for 1 minute Secondary - Chassis : No abnormalities DC 1200V for 1 minute |
| Insulating Resistance | Primary - Chassis : DC 500V 20M ohm or more Secondary - Chassis : DC 500V 20M ohm or more |
| Operating Temperature | Temperature : 0~40℃ ; Humidity : 30%~90% RH(no condensation) |
| Storage environment | Temperature : -20~70℃ ; Humidity : 10%~90% RH (no condensation) |
| Cooling | Speed-Controlled Fan |
| Output terminal | Rear panel terminal or copper bus way |
| Note.1 : All parameters are specified base on power on after 30 minutes, Ambient temperature 23±5 ℃ / Humidity : Under 80% RH, AC Voltage : ±5%, Frequency : ±5%. |
| Note 2. Programming time = Command response time + Output response time. The output response time is differ according to different models, from 40mS ~ 3000mS |
| Model Number Definition : | |
| DSP - 016 - 2500 HP | (1)DSP : Series number. IDRC Programmable DC power Supply. |
| (1) (2) (3) (4) | (2)Output voltage,016 means 16V |
| (3)Output current,2500 means 2500A | |
| (4)HP High power type. |
| Optional Items : | |
| Model Number | Description |
| HP-OPT-RMS | True RMS Current & True Watt |
| HP-OPT-API | Analog Programming interface |
| HP-OPT-CP | Constant Power |
| HP-OPT-IS | Impedance Simulation |
| HP-OPT-PS | Parallel & Series Controller |
Copyright 2019 CHYNG HONG ELECTRONIC CO., LTD. | Contact us |
|||