DSP-WR 系列 1U 宽范围可程式直流电源供应器(CV , CC , CP)
3.4kW规格表 :
TO->
Page 1

HOME

Page 2
  DSP80-128WR DSP160-64WR DSP250-41WR DSP500-20WR
Output voltage
Rated value (V1) 0 ~ 80V 0 ~ 160V 0 ~ 250V 0 ~ 500V
Settable range(*9) 0 ~ 84V 0 ~ 168V 0 ~ 262.5V 0 ~ 525V
Overvoltage protection (OVP) 0% ~ 110% of rated output voltage
Voltage @Rated Current (V2) (速查表) 26.56V 53.13V 82.93V 165.85V
Programming resolution 5 digits
Programming accuracy(*2) ± 0.1% of rated voltage
Meter resolution 5 digits
Meter accuracy(*2) ± 0.1% of rated voltage
Line regulation(*6) ± 0.02% of rated voltage
Load regulation(*7) ± 0.05% of rated voltage
Temperature coefficient for set values 100ppm/°C of rated output voltage, after a 30 minutes warm-up
Ripple & noise (rms) (*3)(*4) < 180mVpp
<20mVrms
<432mVpp
< 35mVrms
< 270mVpp
< 50mVrms
< 315mVpp
< 80mVrms
Full load up <30ms
Full load down <80ms
No load down <5s <10s <10s <10s
Transient Response(*5) < 1.5 ms
Remote compensation
3.84V
7.68V
12V
24V
Output current
Rated value (A1) 0 ~ 128A 0 ~ 64A 0 ~ 41A 0 ~ 20.5A
Settable range(*10) 0 ~ 134.4A 0 ~ 67.2A 0 ~ 43.05A 0 ~ 21.52A
Over current protection (OCP) 0% ~ 110% of rated output current
Current @Rated Voltage (A2) (速查表) 42.5A 21.25A 13.6A 6.8A
Programming resolution 5 digits
Programming accuracy(*2) ± 0.2% of rated current
Meter resolution 5 digits
Meter accuracy(*2) ± 0.2% of rated current
Line regulation(*6) ± 0.05% of rated current
Load regulation(*7) ± 0.15% of rated current
Temperature coefficient for set values 100ppm/°C of rated output voltage, after a 30 minutes warm-up
Ripple & noise(*3)(*4) (with local sense)(CC Mode) 72mA 20mA 16mA 15mA
Output power
Rated value 0 ~ 3.4kW
Settable range(*9) 0 ~ 3468W
Over power protection (OPP) 0% ~ 110% of rated output power
Programming resolution 5 digits
Programming accuracy(*2) < 1% of rated output power
Meter resolution 5 digits
Meter accuracy(*2) ± 0.5% of rated output power
Line regulation(*6) < 0.05% of rated output power
Load regulation(*7) < 0.75% of rated output power
Output Capacitance
Output Capacitance 3760μF 940μF 900μF 225μF
Internal resistance
Adjustment range 0 ~ 0.6250Ω 0 ~ 2.5000Ω 0 ~ 6.0975Ω 0 ~ 24.390Ω
Programming resolution 0.0001Ω 0.0001Ω 0.0001Ω 0.001Ω
Programming Accuracy (*2) <=2.3% of max. resistance
Insulation
Primary - Chassis 2.5 kV DC
Primary - Secondary 2.5 kV DC
Secondary - Chassis 750VDC 750VDC 750VDC 1000VDC
Operating environment Indoor use
Operating temperature
0℃ ~ 45℃
0℃ ~ 45℃
0℃ ~ 50℃
0℃ ~ 50℃
Operating humidity 30%rh ~ 80%rh (no condensation) Max 80% RH up to 30℃, linear decrease to 50% RH at 40℃
Storage temperature -20℃ ~ 70℃
Storage humidity 10%rh ~ 80%rh (no condensation)
Altitude Up to 2000m
Cooling method Forced air cooling using the speed controlled fan
Ground polarity Capable of Negative ground or Positive ground
Input
Nominal input rating 100V ~ 277V 50Hz/60Hz 1-phase 2 wires
Input voltage range
85VAC ~ 305VAC 1-phase 2 wires
Input frequency range 47Hz ~ 63Hz
Current (Max.)(Input 85V/180V) 22.5A 22.5A 21A 21A
Inrush current(Maximum) 40A 40A 40A 40A
Input Power (Maximum) 4kVA 4kVA 3.8kVA 3.8kVA
Efficiency(*15) @277Vin/3.4kW100% Vdc output
<=93.2%
<=93.3%
<=95%
<=95%
Efficiency(*15) @277Vin/3.4kW 100% Vdc output
<=89.3%
<=89.2%
<=92.3%
<=92.3%
Power Factor 0.99 typ.(AC100 ~ 277 input)
Leak current < 3.5 mA
Standard Interface
LAN interfaces 1 x LXI 1.6 for communication,
Optional Analog programming Interface
Status output (dry contact) CV State, CC State , CP State , CR State , ON/OFF State
Voltage control 0% ~ 100% of rated output voltage in the range of 0V ~ 5V or 0V ~ 10V
Voltage control accuracy(*2) +/-0.2%
Current control 0% ~ 100% of rated output current in the range of 0V ~ 5V or 0V ~ 10V
Current control accuracy(*2) +/-0.2%
Power control 0% ~ 100% of rated output current in the range of 0V ~ 5V or 0V ~ 10V
Power control accuracy(*2) +/-0.2%
Monitoring output 0 ~ 5V or 0 ~ 10V output for monitoring V/A/W
Monitoring accuracy (*2) +/-0.2%
Reference output
0 ~ 5VDC or 0 ~ 10VDC (max=5mA), selectable in MENU.
Size and Weight
Enclosure (WxHxD) 430 x 44 x 528.2 mm
Total (WxHxD) 483.6 x 44 x 612.2 mm
Package Dimensions(WxHxD) 600 x 190 x 820 mm
Net weight (kg) 11.2 11.2 11 10.8
Gross weight (kg) 15.8 15.8 15.6 15.4
  DSP80-128WR DSP160-64WR DSP250-41WR DSP500-20WR

*1) 以上数据测试环境:恒温恒湿机内,温度0℃ ~ 50℃,湿度低于80% RH,开机30分钟后,以2% ~ 100%额定输出电压、1% ~ 100%额定输出电流,
    回授补偿点为输出端子,于输出端子测得之平均数据
*2) 精确度项目于室温 23℃ ± 5℃ 测得
*3) Ripple and Noise (rms value) Measurement bandwidth up to 300 kHz
*4) Ripple and Noise (peak value) measurement bandwidth up to 20 MHz
*5) 输出电压到达定值 ±1% 所需时间 (输出电压介于额定值的10% to 90%,以电阻性负载连接,输出额定功率10%以上) (图1)
*6) 恒定负载(1 ~ 100%),输入电压介于180 ~ 264VAC 或 342 ~ 460VAC
*7) CV:恒定输入电压,电流变化介于额定值 10% ~ 90%
    CC:恒定输入电压,电压变化介于额定值 10% ~ 90%
    CP:恒定输入电压,电压*电流变化介于额定值 10% ~ 90%
*8) 输出响应上升时间:电压由额定值 10% 上升至 90% 所需时间
    输出响应下降时间:电压由额定值 90% 下降至 10% 所需时间 (图2)
*9) DSP-WR 系列最高输出电压为额定电压的 105%,但总输出功率不可高于额定功率的102%,此超出规格的电压以线路补偿为目的,不可视为常规使用,且规格特性不在保证范围内。
*10) DSP-WR 系列最大输出电流为额定电流的 105%,但总输出功率不可高于额定功率的102%,此超出规格的电流以线路补偿为目的,不可视为常规使用,且规格特性不在保证范围内。
*11) 电源供应器并联输出特性受线路阻抗等诸多因素影响,多台并联系统的精度参数请与本公司联系。
*12) V1 x A1 ~ V2 x A2 间数值 V 及 A 乘积小于或等于最大功率数值,为宽范围功能可能实现的全部电压和电流组合。
*13) V1可设定最大电流值为A1,A2可设定最大电压值为V2,V1 及 A2 不同时存在
*14) LXI介面反应时间: 100/1000M 网路连线,电脑直接连接至 DSP-WR,封包发送完毕后,至DA开始动作时间间隔。
*15) 因本公司不断追求产品改良,故规格若有变更,恕不另行通知,网页内容仅供参考,实际规格依出货时规格书为准。
*16)擎宏电子保留迳行更动规格及其他产品资讯之权利,并拥有对规格之最终解释权力,且不承担内容之错误或疏失。

图1