DSP-WS 系列 太阳能阵列模拟器(Solar Array Simulator) |
规格表 : | TO-> |
||||
12kW | 12kW | 18kW | 18kW | ||
DSP1000-36WS | DSP1300-27WS | DSP1500-30WS | DSP1950-27WS | ||
Output voltage | |||||
Rated value (V1) | 0 ~ 1000V | 0 ~ 1300V | 0 ~ 1500V | 0 ~ 1950V | |
Settable range | 0 ~ 1050V | 0 ~ 1365V | 0 ~ 1575V | 0 ~ 2047.5V | |
Overvoltage protection (OVP) | 0% ~ 110% of rated output voltage | ||||
Voltage @Rated Current (V2) | 333.33V | 444.44V | 500V | 666.66V | |
Programming resolution | 5 digits | ||||
Programming accuracy(*2) | +/- 0.1% of rated voltage | ||||
Meter resolution | 5 digits | ||||
Meter accuracy(*2) | +/- 0.1% of rated voltage | ||||
Line regulation(*6) | +/- 0.02% of rated voltage | ||||
Load regulation(*7) | +/- 0.05% of rated voltage | ||||
Temperature coefficient for set values | 100ppm/℃ of rated output voltage, after a 30 minutes warm-up | ||||
Ripple & noise (rms) (*3)(*4) | < 1725mVpp < 376mVrms |
<2240mVpp < 490mVrms |
< 2590mVpp < 430mVrms |
< 3360mVpp < 645mVrms |
|
Full load up | <30ms | ||||
Full load down | <80ms | ||||
No load down | <5s | <6s | <5s | <6s | |
Transient Response(*5) | < 1.5 ms | ||||
Remote compensation | 5V | ||||
Output current | |||||
Rated value (A1) | 0 ~ 36A | 0 ~ 27A | 0 ~ 36A | 0 ~ 27A | |
Settable range | 0 ~ 37.8A | 0 ~ 28.35A | 0 ~ 37.8A | 0 ~ 28.35A | |
Over current protection (OCP) | 0% ~ 110% of rated output current | ||||
Current @Rated Voltage (A2) | 10A | 9.23A | 12A | 9.23A | |
Programming resolution | 5 digits | ||||
Programming accuracy(*2) | +/- 0.2% of rated current | ||||
Meter resolution | 5 digits | ||||
Meter accuracy(*2) | +/- 0.2% of rated current | ||||
Line regulation(*6) | +/- 0.05% of rated current | ||||
Load regulation(*7) | +/- 0.15% of rated current | ||||
Temperature coefficient for set values | 100ppm/℃ of rated output voltage, after a 30 minutes warm-up | ||||
Ripple & noise (rms)(*3)(*4) | 24mA | 24mA | 42mA | 42mA | |
Output power | |||||
Rated value | 0 ~ 12kW |
0 ~ 12kW |
0 ~ 18kW |
0 ~ 18kW |
|
Settable range | 0 ~ 12240W |
0 ~ 12240W |
0 ~ 18360W |
0 ~ 18360W |
|
Over power protection (OPP) | 0% ~ 110% of rated output power | ||||
Programming resolution | 5 digits | ||||
Programming accuracy(*2) | < 1% of rated output power | ||||
Meter resolution | 5 digits | ||||
Meter accuracy(*2) | +/- 0.5% of rated output power | ||||
Line regulation(*6) | < 0.05% of rated output power | ||||
Load regulation(*7) | < 0.75% of rated output power | ||||
Internal resistance | |||||
Adjustment range | 0 ~ 27.777Ω | 0 ~ 48.148Ω | 0 ~ 41.666Ω | 0 ~ 72.222Ω | |
Programming resolution | 0.001Ω | 0.001Ω | 0.001Ω | 0.001Ω | |
Programming Accuracy (*2) | <=2.3% of max. resistance | ||||
Insulation | |||||
Primary - Chassis | 2.5 kV DC | ||||
Primary - Secondary | 2.5 kV DC | ||||
Secondary - Chassis | 1500VDC | 2000VDC | 2000VDC | 3000VDC | |
Operating environment | Indoor use | ||||
Operating temperature | 0℃ ~ 50℃ | ||||
Operating humidity | 30%rh ~ 80%rh (no condensation) Max 80% RH up to 30℃, linear decrease to 50% RH at 40℃ | ||||
Storage temperature | -20℃ ~ 70℃ | ||||
Storage humidity | 10%rh ~ 80%rh (no condensation) | ||||
Altitude | Up to 2000m | ||||
Cooling method | Forced air cooling using the speed controlled fan | ||||
Ground polarity | Capable of Negative ground or Positive ground | ||||
Input (output power down to 15kW for 180-264V input, related spec refer to 15kW models) | |||||
Nominal input rating | 380V ~ 415V 50Hz/60Hz 3-phase 3 wires | ||||
Input voltage range |
340VAC ~ 460VAC | ||||
Input frequency range | 47Hz ~ 63Hz | ||||
Current (Maximum) | 26A / Phase (Input 3-phase340V) | 40A / Phase (Input 3-phase340V) | |||
Inrush current(Maximum) | 66A / Phase (Input 3-phase460V) | 99A / Phase (Input 3-phase460V) | |||
Input Power (Maximum) | 14.4kVA | 21.6 kVA | |||
Efficiency | 86 ~ 95% varies by model(*1) | ||||
Power Factor | 0.95 typ. | ||||
Leak current | < 3.5 mA | ||||
Memory & Sequence | |||||
Number of memory | 3 sets (operating in front panel) | ||||
Maximum step number | 500 steps per each Sequence | ||||
Maximum Sequence number | 16 | ||||
Step time settable range | 0.001 sec ~ 999999.999 sec | ||||
Standard Interface | |||||
LAN interfaces | 1 x LXI 1.4 for communication, | ||||
J1 (Auxiliary control) | Function : Interlock , External output ON/OFF , Shut OFF , Alarm signal output, Output voltage downward signal | ||||
Optional Analog programming Interface | |||||
Status output (dry contact) | CV State, CC State , CP State , CR State , ON/OFF State | ||||
Voltage control | 0% ~ 100% of rated output voltage in the range of 0V ~ 5V or 0V ~ 10V | ||||
Voltage control accuracy(*2) | +/-0.2% | ||||
Current control | 0% ~ 100% of rated output current in the range of 0V ~ 5V or 0V ~ 10V | ||||
Current control accuracy(*2) | +/-0.2% | ||||
Power control | 0% ~ 100% of rated output current in the range of 0V ~ 5V or 0V ~ 10V | ||||
Power control accuracy(*2) | +/-0.2% | ||||
Monitoring output | 0 ~ 5V or 0 ~ 10V output for monitoring V/A/W | ||||
Monitoring accuracy (*2) | +/-0.2% | ||||
Reference output |
0 ~ 5VDC or 0 ~ 10VDC (max=5mA), selectable in MENU. | ||||
Optional RS-485 programming Interface | |||||
Baud rate | 4800/9600/19200/38400/57600/115200 | ||||
Line ending character | Cr , Lf , Cr+Lf selectable | ||||
Optional GPIB programming Interface | |||||
IEEE Std 488.2.1992 | |||||
Size and Weight | |||||
Enclosure (WxHxD) | 440 x 129 x 660 mm | ||||
Dimensions(WxHxD) | 482 x 132 x 765.1 mm | ||||
Weight (kg) | 34.8 | 34.8 | 43.6 | 43.6 | |
DSP1000-36WS | DSP1300-27WS | DSP1500-30WS | DSP1950-23WS |
*1) 以上数据测试环境:恒温恒湿机内,温度0℃
~ 50℃,湿度低于80% RH,开机30分钟后,以2% ~ 100%额定输出电压、1% ~ 100%额定输出电流, 回授补偿点为输出端子,于输出端子测得之平均数据 |
*2) 精确度项目于室温 23℃ ± 5℃ 测得 |
*3) Ripple and Noise (rms value) Measurement bandwidth up to 300 kHz |
*4) Ripple and Noise (peak value) measurement bandwidth up to 20 MHz |
*5) 输出电压到达定值 ±1% 所需时间 (输出电压介于额定值的10% to 90%,以电阻性负载连接,输出额定功率10%以上) (图1) |
*6) 恒定负载(1 ~ 100%),输入电压介于180 ~ 264VAC 或 342 ~ 460VAC |
*7) CV:恒定输入电压,电流变化介于额定值
10% ~ 90% CC:恒定输入电压,电压变化介于额定值 10% ~ 90% CP:恒定输入电压,电压*电流变化介于额定值 10% ~ 90% |
*8) 输出响应上升时间:电压由额定值 10%
上升至 90% 所需时间 输出响应下降时间:电压由额定值 90% 下降至 10% 所需时间 (图2) |
*9) DSP-WS 系列最高输出电压为额定电压的 105%,但总输出功率不可高于额定功率的102%,此超出规格的电压以线路补偿为目的,不可视为常规使用,且规格特性不在保证范围内。 |
*10) DSP-WS 系列最大输出电流为额定电流的 105%,但总输出功率不可高于额定功率的102%,此超出规格的电流以线路补偿为目的,不可视为常规使用,且规格特性不在保证范围内。 |
*11) 电源供应器并联输出特性受线路阻抗等诸多因素影响,多台并联系统的精度参数请与本公司联系。 |
*12) V1 x A1 ~ V2 x A2 间数值 V 及 A 乘积小于或等于最大功率数值,为宽范围功能可能实现的全部电压和电流组合。 |
*13) V1可设定最大电流值为A1,A2可设定最大电压值为V2,V1 及 A2 不同时存在 |
*14) LXI介面反应时间: 100/1000M 网路连线,电脑直接连接至 DSP-WR,封包发送完毕后,至DA开始动作时间间隔。 |
*15) 倍率随机种不同略有差异。 |
*16) 效率随机种不同略有差异。 |
*17) 因本公司不断追求产品改良,故规格若有变更,恕不另行通知,网页内容仅供参考,实际规格依出货时规格书为准。 |
*18)擎宏电子保留迳行更动规格及其他产品资讯之权利,并拥有对规格之最终解释权力,且不承担内容之错误或疏失。 |
图1 |
图2 |
![]() |
![]() |
|
|||
|
|||