| Features |
|
|
|
|
| |
- Wide Range Output : DC output 0~80V/128A to 0~1500V/6.8A(*1)
- Wide Range Input : Max. : AC mains 85~305V (47~63Hz), Rating : 100V~277Vac (50/60Hz)
- Power Regulated by Input Voltage : AC200V~277V(3.4kW) ; AC100V~120V(1.5kW)
- True parallel operation allows the master unit to set and display the total output current.
- Internal clock rate synchronization reduces electromagnetic interference, enhancing system
stability and overall efficiency.
- Built-in patented synchronizing circuitry allows easy integration of 32 units.
- High Active Power Factor Correction. Totem-Pole PFC design, PF > 0.99
- Efficiency has nearly 95%. (each stage PFC, D2D, BUCK
> 98%)(*2) (*3
)
|
| Electrical |
| |
|
| Operational |
| |
- 320x240 display resolution with rotary knobs and buttons give a clear and intuitive control.
- Patented dual-function key design for enhanced operation convenience.
- Independent voltage and current control with rotary encoder ; adjustable digit resolution on
panel for precise operation.
- Two panel output adjustment modes: real-time or confirmation required.
- Supports output ramp-up and ramp-down and slew rate control of voltage, current and power.
- Programmable over-voltage and over-current protection.
- Provides time-stamped operation log for traceability.
|
| Safety |
|
| |
- Intelligent speed-controlled fan to reduce acoustic noise effectively.
- Seamless parallel stacking to save space.
- All models are equipped with equip with auto-discharge circuit, discharge voltage to safe range within 10 seconds after output OFF(<60V).
- Built-in timer allows voltage and current runtime settings and countdown function.
- Settable power-on output mode to prevents test interruption or DUT damage after power recovery.
- Firmware upgrade via USB/LAN without opening the case; protected against power loss.
- Built-in RTC; Supports network time synchronization with user-defined NTP server and maintains
accuracy without connection.
- CE approved.
- ISTA 3A Vibration Test and Filled Transport Packages Test approved.
|
| Interface |
| |
- Dual LAN ports as standard (LXI 1.6 compliant); interface response time as fast as 3 ms.
- National Instruments certified IVI-C Driver provided.
- Alarm signal output and InterLock control contacts for integration with external control systems to
enhance operational safety.
- SCPI compatible
- Easy comparision between wide range and traditional DC power supply with cumtomized program. (Download)
|