Maximum Voltage vs. Maximum Current |
|
Rating Power (W) |
Model | Maximum Voltage (V1) |
Maximum Current at Maximum Voltage (A1) |
Maximum Voltage at Maximum Current (V2) |
Maximum Current (A2) |
10kW | DSP1000-30WS / As |
1000 V |
10 A |
333.33 V |
30 A |
DSP1300-23WS / As |
1300 V |
7.69 A |
434.78 V |
23 A |
|
12kW | DSP1000-36WS / As |
1000 V |
12 A |
333.33 V |
36 A |
DSP1300-27WS / As
|
1300 V |
9.23 A |
444.44 V |
27 A |
|
15kW | DSP1050-42WS / As |
1050 V |
14.28 A |
357.14 V |
42 A |
DSP1500-30WS / As |
1500 V |
10 A |
500 V |
30 A |
|
DSP1950-23WS / As |
1950 V |
7.69 A |
652.17 V |
23 A |
|
18kW | DSP1500-36WS / As |
1500 V |
12 A |
500 V |
36 A |
DSP1950-27WS / As
|
1950 V |
9.23 A |
666.66 V |
27 A |
Model Numbering : | |
DSP xxxxV - xxxxA Wxx | (1) DSP : Programmable DC power supply |
(1) (2) (3) (4) | (2) xxxxV: Maximum Output Voltage, ex. 80, 500, or 1500 |
(3) xxxxA : Maximum Output Current, ex. 540, 90 or 30 | |
(4) Wxx : there are 6 models as follows: WR : Model with CV, CC and CP control WE : Model with CV and CC control WS : Solar Array Simulator WA : Salve of WR, blank panel WAe : Slave of WE, blank panel WAs : Slave of WS, blank panel |
|
Copyright 2019 CHYNG HONG ELECTRONIC CO., LTD. | Contact us |