DSP-WE 系列 寬範圍可程式直流電源供應器(CV , CC) |
18kW規格表 : | TO-> |
||||
DSP80-360WE | DSP160-180WE | DSP250-120WE | DSP350-84WE | DSP500-60WE | DSP650-46WE | DSP1000-30WE | DSP1300-23WE | |
Output voltage | ||||||||
Rated value (V1) | 0~80V | 0~160V | 0~250V | 0~350V | 0~500V | 0~650V | 0~1000V | 0~1300V |
Settable range(*9) | 0~84V | 0~168V | 0~262.5V | 0~367.5V | 0~525V | 0~682.5V | 0~1050V | 0~1365V |
Overvoltage protection (OVP) | 0%∼110% of rated output voltage | |||||||
Voltage @Rated Current (V2) (速查表) | 27.78V | 55.55V | 83.33V | 119.05V | 166.67V | 217.39V | 333.33V | 434.78V |
Programming resolution | 5 digits | |||||||
Programming accuracy(*2) | ± 0.1% of rated voltage | |||||||
Meter resolution | 5 digits | |||||||
Meter accuracy(*2) | ± 0.1% of rated voltage | |||||||
Line regulation(*6) | ± 0.02% of rated voltage | |||||||
Load regulation(*7) | ± 0.05% of rated voltage | |||||||
Temperature coefficient for set values | 100ppm/°C of rated output voltage, after a 30 minutes warm-up | |||||||
Ripple & noise (rms) (*3)(*4) | < 288mVpp < 23mVrms |
< 432mVpp < 35mVrms |
< 270mVpp < 36mVrms |
< 288mVpp < 50mVrms |
< 315mVpp <63mVrms |
< 720mVpp < 180mVrms |
< 1440mVpp < 315mVrms |
<2240mVpp < 490mVrms |
Full load up | <30ms | |||||||
Full load down | <80ms | |||||||
No load down | <5s | <5s | <10s | <10s | <5s | <6s | <5s | <6s |
Transient Response(*5) | < 1.5 ms | |||||||
Remote compensation | 5V | |||||||
Output current | ||||||||
Rated value (A1) | 0~360A | 0~180A | 0~120A | 0~84A | 0~60A | 0~46A | 0~30A | 0~23A |
Settable range(*10) | 0~378A | 0~189A | 0~126A | 0~88.2A | 0~63A | 0~48.3A | 0~31.5A | 0~24.15A |
Over current protection (OCP) | 0%∼110% of rated output current | |||||||
Current @Rated Voltage (A2) (速查表) | 125A | 62.5A | 40A | 28.56A | 20A | 15.38A | 10A | 7.69A |
Programming resolution | 5 digits | |||||||
Programming accuracy(*2) | ± 0.2% of rated current | |||||||
Meter resolution | 5 digits | |||||||
Meter accuracy(*2) | ± 0.2% of rated current | |||||||
Line regulation(*6) | ± 0.05% of rated current | |||||||
Load regulation(*7) | ± 0.15% of rated current | |||||||
Temperature coefficient for set values | 100ppm/°C of rated output voltage, after a 30 minutes warm-up | |||||||
Ripple & noise (rms)(*3)(*4) | 144mA | 72mA | 38mA | 32mA | 29mA | 29mA | 20mA | 20mA |
Output power | ||||||||
Rated value | 10kW | |||||||
Meter resolution | 5 digits | |||||||
Meter accuracy(*2) | ± 0.5% of rated output power | |||||||
Line regulation(*6) | < 0.05% of rated output power | |||||||
Load regulation(*7) | < 0.75% of rated output power | |||||||
Insulation | ||||||||
Primary - Chassis | 2.5 kV DC | |||||||
Primary - Secondary | 2.5 kV DC | |||||||
Secondary - Chassis | 750VDC | 750VDC | 750VDC | 750VDC | 1000VDC | 1500VDC | 1500VDC | 2000VDC |
Operating environment | Indoor use | |||||||
Operating temperature | 0℃ ~ 50℃ | |||||||
Operating humidity | 30%rh ~ 80%rh (no condensation) Max 80% RH up to 30℃, linear decrease to 50% RH at 40℃ | |||||||
Storage temperature | -20℃ ~ 70℃ | |||||||
Storage humidity | 10%rh ~ 80%rh (no condensation) | |||||||
Altitude | Up to 2000m | |||||||
Cooling method | Forced air cooling using the speed controlled fan | |||||||
Ground polarity | Capable of Negative ground or Positive ground | |||||||
Input | ||||||||
Nominal input rating | 200V ~ 415V 50Hz/60Hz 3-phase 3 wires , Optional 480V 50/60Hz 3-phase 4 wires | |||||||
Input voltage range |
180VAC ~ 460VAC , Optional 480VAC (type:432VAC ~ 528VAC) | |||||||
Input frequency range | 47Hz ~ 63Hz | |||||||
Current (Maximum) | 40A (Input 3-phase 180V) | |||||||
Inrush current(Maximum) | 66A (Input 3-phase 460V) | |||||||
Input Power (Maximum) | 12kVA | 12kVA | 12kVA | 12kVA | 12kVA | 12kVA | 12kVA | 12kVA |
Efficiency | 86~95% varies by model(*1) | |||||||
Power Factor | 0.99 typ.(480V input) / 0.95 typ.(200V ~ 415V input) | |||||||
Leak current | < 3.5 mA | |||||||
Memory & Sequence | ||||||||
Number of memory | 3 sets (operating in front panel) | |||||||
Maximum step number | 500 steps per each Sequence | |||||||
Maximum Sequence number | 16 | |||||||
Step time settable range | 0.001 sec ~ 999999.999 sec | |||||||
Standard Interface | ||||||||
LAN interfaces | 1 x LXI 1.4 for communication, | |||||||
J1 (Auxiliary control) | Function : Interlock , External output ON/OFF , Shut OFF , Alarm signal output, Output voltage downward signal | |||||||
Optional Analog programming Interface | ||||||||
Status output (dry contact) | CV State, CC State , ON/OFF State | |||||||
Voltage control | 0% ~ 100% of rated output voltage in the range of 0V ~ 5V or 0V ~ 10V | |||||||
Voltage control accuracy(*2) | +/-0.2% | |||||||
Current control | 0% ~ 100% of rated output current in the range of 0V ~ 5V or 0V ~ 10V | |||||||
Current control accuracy(*2) | +/-0.2% | |||||||
Monitoring output | 0~5V or 0~10V output for monitoring V/A | |||||||
Monitoring accuracy (*2) | +/-0.2% | |||||||
Reference output |
0~5VDC or 0~10VDC (max=5mA), selectable in MENU. | |||||||
Optional RS-485 programming Interface | ||||||||
Baud rate | 4800/9600/19200/38400/57600/115200 | |||||||
Line ending character | Cr , Lf , Cr+Lf selectable | |||||||
Optional GPIB programming Interface | ||||||||
IEEE Std 488.2.1992 | ||||||||
Size and Weight | ||||||||
Enclosure (WxHxD) | 440 x 129 x 660 mm | |||||||
Total (WxHxD) | 482 x 132 x 765.1 mm | |||||||
Weight (kg) | 36.3 | 36.3 | 34.8 | 34.8 | 34.8 | 34.8 | 34.8 | 34.8 |
DSP080-360WE | DSP160-180WE | DSP250-120WE | DSP350-84WE | DSP500-60WE | DSP650-46WE | DSP1000-30WE | DSP1300-23WE |
*1) 以上數據測試環境:恆溫恆濕機內,溫度0℃
~ 50℃,濕度低於80% RH,開機30分鐘後,以2%~100%額定輸出電壓、1%~100%額定輸出電流, 回授補償點為輸出端子,於輸出端子測得之平均數據 |
*2) 精確度項目於室溫 23℃ ± 5℃ 測得 |
*3) Ripple and Noise (rms value) Measurement bandwidth up to 300 kHz |
*4) Ripple and Noise (peak value) measurement bandwidth up to 20 MHz |
*5) 輸出電壓到達定值 ±1% 所需時間 (輸出電壓介於額定值的10% to 90%,以電阻性負載連接,輸出額定功率10%以上) (圖1) |
*6) 恆定負載(1~100%),輸入電壓介於180 ~ 264VAC 或 342 ~ 460VAC |
*7) CV:恆定輸入電壓,電流變化介於額定值
10% ~ 90% CC:恆定輸入電壓,電壓變化介於額定值 10% ~ 90% CP:恆定輸入電壓,電壓*電流變化介於額定值 10% ~ 90% |
*8) 輸出響應上升時間:電壓由額定值 10%
上升至 90% 所需時間 輸出響應下降時間:電壓由額定值 90% 下降至 10% 所需時間 (圖2) |
*9) DSP-WE 系列最高輸出電壓為額定電壓的 105%,但總輸出功率不可高於額定功率的102%,此超出規格的電壓以線路補償為目的,不可視為常規使用,且規格特性不在保證範圍內。 |
*10) DSP-WE 系列最大輸出電流為額定電流的 105%,但總輸出功率不可高於額定功率的102%,此超出規格的電流以線路補償為目的,不可視為常規使用,且規格特性不在保證範圍內。 |
*11) 電源供應器並聯輸出特性受線路阻抗等諸多因素影響,多台並聯系統的精度參數請與本公司聯繫。 |
*12) V1 x A1 ~ V2 x A2 間數值 V 及 A 乘積小於或等於最大功率數值,為寬範圍功能可能實現的全部電壓和電流組合。 |
*13) V1可設定最大電流值為A1,A2可設定最大電壓值為V2,V1 及 A2 不同時存在 |
*14) LXI介面反應時間: 100/1000M 網路連線,電腦直接連接至 DSP-WR,封包發送完畢後,至DA開始動作時間間隔。 |
*15) 因本公司不斷追求產品改良,故規格若有變更,恕不另行通知,網頁內容僅供參考,實際規格依出貨時規格書為準。 |
*16)擎宏電子保留逕行更動規格及其他產品資訊之權利,並擁有對規格之最終解釋權力,且不承擔內容之錯誤或疏失。 |